The general design of the medical ward door size is M1321, and the width generally must be 1.3 meters to ensure that the bed can pass through; the anti-collision aluminum alloy will be spliced at the edge of the door or at a position of 800mm high, and the ward door generally requires high waterproof and moisture-proof properties. These are relatively speaking, ordinary door does not have high requirements.
The following are the points to pay attention to when installing and measuring the size of the medical ward door:
Measurement before installation of ward door
The most commonly used ward door measurement methods are the international measurement method and the Chinese measurement method.
1. International measurement method: The installer is required to stand at a position about two meters away from the opening of the ward, and use our portable international measuring tape to measure the verticality, width and height of the left and right walls and the top wall to the narrowest ground, and the thickness Measure at the widest point. (Requires repeated measurement to ensure accuracy)
2. Chinese-style measurement method: First, use our standard tape measure to measure the width and height of the ward door. After the measurement is completed, take the smallest value of the above width and height as the accurate value. Next, measure the thickness of the wall, measure the thickness of the left and right walls of the hole and the top wall respectively, and use the largest measurement value as the standard size.
The measurement method of the hospital opening
The measurement of the hospital opening is slightly complicated. First, the height: use a tape measure to measure the distance between the upper and lower sides of the opening (tighten the tape to avoid errors when measuring). It requires multiple measurements to different measurement points, with the smallest value as the standard size, as the height size. Secondly, measure the width of the opening: measure the distance between the left and right walls of the opening. At the same time, it is required to perform multiple measurements on different measuring points with the smallest value as the standard size as the width of the door leaf. Note: When I measure, I should pay attention to the ground treatment and the thickness of the wall during the measurement. If the wall still needs to be decorated, the thickness of the decoration material should be added to the wall of the opening.
Door size between various areas of the hospital
1. Single door: standard 700-1000*2100mm, suitable for ward doors, giving patients a safe and comfortable feeling.
2. Son-mother door: as the name implies, two doors, one large and one small, with a size of 1200*2100mm, which is suitable for hospital conference rooms, laboratories, and laboratories, giving people a vigorous atmosphere.
3. Side door: standard size 1500*2100mm, suitable for operating room door, safe passage door, corridor door, convenient for the entry and exit of surgical carts and drug products
4. Ward bathroom door: standard size 600*2100, usually one entry and exit does not need to be too large.